# ErP regulatory datasheets for VMI® products (Eco-design directive no. 1254/2014/EU)

| Name of the VMI® model | Purevent |
| --- | --- |
| Supplier’s name | Ventilairsec |
| Energy rating | B |
| Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,7 |
| Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -53,7 |
| Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,1 |
| Flow type | Unidirectional (SF) |
| Declared type | RVU |
| Type of drive installed or planned | Variable speed |
| Type of heat recovery system | N/A |
| Thermal efficiency of the heat recovery system (%) | N/A |
| Maximum RVU flow rate (m3/h) | 349,8 |
| Power input at Qmax (W) | 74,4 |
| LwA – Sound power level (dB(A)) | 31,1 |
| Reference flow rate (m3/s) | 0,096 |
| Reference pressure (Pa) | 50 |
| SPI (kW/m3/h) | 0,00012 |
| Control factor (CTRL) (%) | 0,65 |
| Type of control | Local modulated control |
| Maximum external leakage rate for under-pressure (%) | 0,5 |
| Maximum external leakage rate for overpressure (%) | 0,5 |
| Maximum internal leakage rate for under-pressure (%) | N/A |
| Maximum internal leakage rate for overpressure (%) | N/A |
| Filter warning information | See manual |
| Regular filter changes to ensure unit performance and energy efficiency | See manual |
| Installation instructions for ventilation grilles | See manual |
| Pre-/dis-assembly instructions (Internet) | See manual |
| Airflow sensitivity to pressure variations at +20 Pa | N/A |
| Airflow sensitivity to pressure variations at -20 Pa | N/A |
| Indoor/outdoor air tightness (m3/h) | N/A |
| Annual power consumption kWh/year | 0,66 |
| Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
| Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
| Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |

| Name of the VMI® model | Urban 2 |
| --- | --- |
| Supplier’s name | Ventilairsec |
| Energy rating | B |
| Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -27,8 |
| Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -54,8 |
| Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -12,3 |
| Flow type | Unidirectional (SF) |
| Declared type | RVU |
| Type of drive installed or planned | Variable speed |
| Type of heat recovery system | N/A |
| Thermal efficiency of the heat recovery system (%) | N/A |
| Maximum RVU flow rate (m3/h) | 150 |
| Power input at Qmax (W) | 7,6 |
| LwA – Sound power level (dB(A)) | 46 |
| Reference flow rate (m3/s) | 0,029 |
| Reference pressure (Pa) | 15 |
| SPI (kW/m3/h) | 0,00004 |
| Control factor (CTRL) (%) | 0,65 |
| Type of control | Local modulated control |
| Maximum external leakage rate for under-pressure (%) | _ |
| Maximum external leakage rate for overpressure (%) | 4,4 |
| Maximum internal leakage rate for under-pressure (%) | N/A |
| Maximum internal leakage rate for overpressure (%) | N/A |
| Filter warning information | See manual |
| Regular filter changes to ensure unit performance and energy efficiency | See manual |
| Installation instructions for ventilation grilles | See manual |
| Pre-/dis-assembly instructions (Internet) | See manual |
| Airflow sensitivity to pressure variations at +20 Pa | N/A |
| Airflow sensitivity to pressure variations at -20 Pa | N/A |
| Indoor/outdoor air tightness (m3/h) | N/A |
| Annual power consumption kWh/year | 0,22 |
| Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,30 |
| Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
| Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |

| Name of the VMI® model | Pro 1000 |
| --- | --- |
| Ventilairsec | Simple content |
| Declared type | UVNR simple flux |
| Type of drive installed or planned | Variable Speed Drive (VSD) |
| Type of heat recovery system | None |
| Thermal efficiency of the heat recovery system (%) | N/A |
| Nominal flow rate for the NRVU (m3/s) | 0,139 |
| Nominal electric power input (kW) | 0,075 |
| SFPint (W/m3/s) | 230 |
| Face velocity at design flow rate (m/s) | 1,33 |
| External nominal pressure – Δps, ext (Pa) | 141 |
| Internal pressure drop for ventilation components – Δps, int (Pa) | 53 |
| Internal pressure drop for components not involved in ventilation – Δps, add (Pa) | N/A |
| Static efficiency of the fans used | 0,455 |
| Maximum external leakage rate declared (%) | 3 |
| Filter warning information | The “filter full” pictogram is flashing in the control unit fitted in the ventilated space; the yellow LED is also flashing. |
| Regular filter changes to ensure unit performance and energy efficiency | See manual |

| Name of the VMI® model | Cube Vision’R |
| --- | --- |
| Supplier’s name | Ventilairsec |
| Energy rating | B |
| Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,6 |
| Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -53,7 |
| Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,1 |
| Flow type | Unidirectional (SF) |
| Declared type | RVU |
| Type of drive installed or planned | Variable speed |
| Type of heat recovery system | N/A |
| Thermal efficiency of the heat recovery system (%) | N/A |
| Maximum RVU flow rate (m3/h) | 200 |
| Power input at Qmax (W) | 44 |
| LwA – Sound power level (dB(A)) | 42 |
| Reference flow rate (m3/s) | 0,039 |
| Reference pressure (Pa) | 50 |
| SPI (kW/m3/h) | 0,00013 |
| Control factor (CTRL) (%) | 0,65 |
| Type of control | Local modulated control |
| Maximum external leakage rate for under-pressure (%) | 12,7 |
| Maximum external leakage rate for overpressure (%) | 11,9 |
| Maximum internal leakage rate for under-pressure (%) | N/A |
| Maximum internal leakage rate for overpressure (%) | N/A |
| Filter warning information | See manual |
| Regular filter changes to ensure unit performance and energy efficiency | See manual |
| Installation instructions for ventilation grilles | See manual |
| Pre-/dis-assembly instructions (Internet) | See manual |
| Airflow sensitivity to pressure variations at +20 Pa | N/A |
| Airflow sensitivity to pressure variations at -20 Pa | N/A |
| Indoor/outdoor air tightness (m3/h) | N/A |
| Annual power consumption kWh/year | 0,68 |
| Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
| Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
| Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |

| Name of the VMI® model | Cave |
| --- | --- |
| Supplier’s name | Ventilairsec |
| Energy rating | F |
| Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -6,8 |
| Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -23,2 |
| Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | 2,6 |
| Flow type | Unidirectional (SF) |
| Declared type | RVU |
| Type of drive installed or planned | Plusieurs vitesses |
| Type of heat recovery system | N/A |
| Thermal efficiency of the heat recovery system (%) | N/A |
| Maximum RVU flow rate (m3/h) | 148,7 |
| Power input at Qmax (W) | 62 |
| LwA – Sound power level (dB(A)) | 52 |
| Reference flow rate (m3/s) | 0,054 |
| Reference pressure (Pa) | 50,1 |
| SPI (kW/m3/h) | 0,00033 |
| Control factor (CTRL) (%) | 1 |
| Type of control | Manual control |
| Maximum external leakage rate for under-pressure (%) | 32,6 |
| Maximum external leakage rate for overpressure (%) | 30,2 |
| Maximum internal leakage rate for under-pressure (%) | N/A |
| Maximum internal leakage rate for overpressure (%) | N/A |
| Filter warning information | See manual |
| Regular filter changes to ensure unit performance and energy efficiency | See manual |
| Installation instructions for ventilation grilles | See manual |
| Pre-/dis-assembly instructions (Internet) | See manual |
| Airflow sensitivity to pressure variations at +20 Pa | N/A |
| Airflow sensitivity to pressure variations at -20 Pa | N/A |
| Indoor/outdoor air tightness (m3/h) | N/A |
| Annual power consumption kWh/year | 4,13 |
| Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 17,15 |
| Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 33,55 |
| Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 7,76 |

# Energy labels for VMI® products

[VMI Cave Label](https://www.vmi-technologies.com/wp-content/uploads/2024/09/ERP-Cave.pdf)

[VMI Cube Label](https://www.vmi-technologies.com/wp-content/uploads/2024/09/ERP-Cube.pdf)

[VMI Urban 2](https://www.vmi-technologies.com/wp-content/uploads/2026/02/ETIQUETTE-ENERGETIQUE-URBAN-2.pdf)

[VMI Purevent Label](https://www.vmi-technologies.com/wp-content/uploads/2024/09/ERP-Purevent.pdf)