Name of the VMI® model | |
---|---|
Supplier’s name | Ventilairsec |
Energy rating | B |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,7 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -53,7 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,1 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Variable speed |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 349,8 |
Power input at Qmax (W) | 74,4 |
LwA – Sound power level (dB(A)) | 31,1 |
Reference flow rate (m3/s) | 0,096 |
Reference pressure (Pa) | 50 |
SPI (kW/m3/h) | 0,00012 |
Control factor (CTRL) (%) | 0,65 |
Type of control | Local modulated control |
Maximum external leakage rate for under-pressure (%) | 0,5 |
Maximum external leakage rate for overpressure (%) | 0,5 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 0,66 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |
Name of the VMI® model | |
---|---|
Supplier’s name | Ventilairsec |
Energy rating | B |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,9 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -54 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,4 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Variable speed |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 185,6 |
Power input at Qmax (W) | 22,2 |
LwA – Sound power level (dB(A)) | 51 |
Reference flow rate (m3/s) | 0,038 |
Reference pressure (Pa) | 50 |
SPI (kW/m3/h) | 0,0001 |
Control factor (CTRL) (%) | 0,65 |
Type of control | Local modulated control |
Maximum external leakage rate for under-pressure (%) | 12,3 |
Maximum external leakage rate for overpressure (%) | 14 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 0,55 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,81 |