Pour offrir les meilleures expériences, nous utilisons des technologies telles que les cookies pour stocker et/ou accéder aux informations des appareils. Le fait de consentir à ces technologies nous permettra de traiter des données telles que le comportement de navigation ou les ID uniques sur ce site. Le fait de ne pas consentir ou de retirer son consentement peut avoir un effet négatif sur certaines caractéristiques et fonctions.
Name of the VMI® model | Purevent |
|---|---|
Supplier’s name | Ventilairsec |
Energy rating | B |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,7 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -53,7 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,1 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Variable speed |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 349,8 |
Power input at Qmax (W) | 74,4 |
LwA – Sound power level (dB(A)) | 31,1 |
Reference flow rate (m3/s) | 0,096 |
Reference pressure (Pa) | 50 |
SPI (kW/m3/h) | 0,00012 |
Control factor (CTRL) (%) | 0,65 |
Type of control | Local modulated control |
Maximum external leakage rate for under-pressure (%) | 0,5 |
Maximum external leakage rate for overpressure (%) | 0,5 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 0,66 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |
Name of the VMI® model | Urban 2 |
|---|---|
Supplier’s name | Ventilairsec |
Energy rating | B |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -27,8 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -54,8 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -12,3 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Variable speed |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 150 |
Power input at Qmax (W) | 7,6 |
LwA – Sound power level (dB(A)) | 46 |
Reference flow rate (m3/s) | 0,029 |
Reference pressure (Pa) | 15 |
SPI (kW/m3/h) | 0,00004 |
Control factor (CTRL) (%) | 0,65 |
Type of control | Local modulated control |
Maximum external leakage rate for under-pressure (%) | _ |
Maximum external leakage rate for overpressure (%) | 4,4 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 0,22 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,30 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |
Name of the VMI® model | Pro 1000 |
|---|---|
Ventilairsec | Simple content |
Declared type | UVNR simple flux |
Type of drive installed or planned | Variable Speed Drive (VSD) |
Type of heat recovery system | None |
Thermal efficiency of the heat recovery system (%) | N/A |
Nominal flow rate for the NRVU (m3/s) | 0,139 |
Nominal electric power input (kW) | 0,075 |
SFPint (W/m3/s) | 230 |
Face velocity at design flow rate (m/s) | 1,33 |
External nominal pressure – Δps, ext (Pa) | 141 |
Internal pressure drop for ventilation components – Δps, int (Pa) | 53 |
Internal pressure drop for components not involved in ventilation – Δps, add (Pa) | N/A |
Static efficiency of the fans used | 0,455 |
Maximum external leakage rate declared (%) | 3 |
Filter warning information | The “filter full” pictogram is flashing in the control unit fitted in the ventilated space; the yellow LED is also flashing. |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Name of the VMI® model | Cube Vision’R |
|---|---|
Supplier’s name | Ventilairsec |
Energy rating | B |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -26,6 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -53,7 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | -11,1 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Variable speed |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 200 |
Power input at Qmax (W) | 44 |
LwA – Sound power level (dB(A)) | 42 |
Reference flow rate (m3/s) | 0,039 |
Reference pressure (Pa) | 50 |
SPI (kW/m3/h) | 0,00013 |
Control factor (CTRL) (%) | 0,65 |
Type of control | Local modulated control |
Maximum external leakage rate for under-pressure (%) | 12,7 |
Maximum external leakage rate for overpressure (%) | 11,9 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 0,68 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 28,3 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 55,36 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 12,80 |
Name of the VMI® model | Cave |
|---|---|
Supplier’s name | Ventilairsec |
Energy rating | F |
Average climate – SEC – Specific Energy Consumption (kWh/m2.year) | -6,8 |
Cold climate – SEC – Specific Energy Consumption (kWh/m2.year) | -23,2 |
Warm climate – SEC – Specific Energy Consumption (kWh/m2.year) | 2,6 |
Flow type | Unidirectional (SF) |
Declared type | RVU |
Type of drive installed or planned | Plusieurs vitesses |
Type of heat recovery system | N/A |
Thermal efficiency of the heat recovery system (%) | N/A |
Maximum RVU flow rate (m3/h) | 148,7 |
Power input at Qmax (W) | 62 |
LwA – Sound power level (dB(A)) | 52 |
Reference flow rate (m3/s) | 0,054 |
Reference pressure (Pa) | 50,1 |
SPI (kW/m3/h) | 0,00033 |
Control factor (CTRL) (%) | 1 |
Type of control | Manual control |
Maximum external leakage rate for under-pressure (%) | 32,6 |
Maximum external leakage rate for overpressure (%) | 30,2 |
Maximum internal leakage rate for under-pressure (%) | N/A |
Maximum internal leakage rate for overpressure (%) | N/A |
Filter warning information | See manual |
Regular filter changes to ensure unit performance and energy efficiency | See manual |
Installation instructions for ventilation grilles | See manual |
Pre-/dis-assembly instructions (Internet) | See manual |
Airflow sensitivity to pressure variations at +20 Pa | N/A |
Airflow sensitivity to pressure variations at -20 Pa | N/A |
Indoor/outdoor air tightness (m3/h) | N/A |
Annual power consumption kWh/year | 4,13 |
Average climate – AHS – Annual Heating Saved (kWh/m2.year) | 17,15 |
Cold climate – AHS – Annual Heating Saved (kWh/m2.year) | 33,55 |
Warm climate – AHS – Annual Heating Saved (kWh/m2.year) | 7,76 |