| Parameter | Value |
|---|---|
| VMI® model designation | EYOTA 300 CO2 LH et EYOTA 300 RH |
| Supplier name | Ventilairsec |
| Energy class | A+ |
| Average climate – SEC – Specific energy consumption (kWh/(m2 a)) | -42.38 |
| Cold climate – SEC – Specific energy consumption (kWh/(m2 a)) | -16.78 |
| Warm climate – SEC – Specific energy consumption (kWh/(m2 a)) | -87.85 |
| Flow type | Double flow |
| Declared typology | RVU/BVU |
| Type of drive installed or intended | Variable speed |
| Type of heat recovery system | Heat recovery |
| Thermal efficiency of heat recovery (%) | 93 |
| Maximum flow rate of RVU (m3/h) | 300 |
| Electric power input at Qmax (W) | 166 |
| LwA – Sound power level (dB(A)) | 48.5 |
| Reference flow rate (m3/s) | 0.05833 |
| Reference pressure (Pa) | 50 |
| SPI (kW/m3/h) | 0.36 |
| Control factor CTRL (%) | N/A |
| Control typology | Local demand control |
| Max. internal and external leakage rate (%) of BVUs | <5% internal / <5% external |
| Filter alarm information | See manual |
| Regular filter replacement for unit performance and efficiency | See manual |
| Installation instructions for ventilation grilles | See manual |
| Preassembly/disassembly instructions (internet) | See manual |
| Airflow sensitivity to pressure variations at + 20 Pa | N/A |
| Airflow sensitivity to pressure variations at - 20 Pa | N/A |
| Indoor/outdoor airtightness (m3/h) | N/A |
| Annual electricity consumption (kWh/a) | 2.34 |
| Average climate – AHS – Annual heating saving (kWh/(m2.a)) | 47.56 |
| Cold climate – AHS – Annual heating saving (kWh/(m2.a)) | 93.03 |
| Warm climate – AHS – Annual heating saving (kWh/(m2.a)) | 21.50 |
| Parameter | Value |
|---|---|
| VMI® model designation | EYOTA 450 CO2 LH et EYOTA 450 RH |
| Supplier name | Ventilairsec |
| Energy class | A+ |
| Average climate - SEC - Specific energy consumption (kWh/(m2 a)) | -44,38 |
| Cold climate - SEC - Specific energy consumption (kWh/(m2 a)) | -89,46 |
| Warm climate - SEC - Specific energy consumption (in kWh/(m2 a)) | -19,01 |
| Type of flow | DF |
| Declared typology | RVU/BVU |
| Type of motorization installed or planned | Variable speed |
| Type of heat recovery system | Recovery unit |
| Thermal efficiency of heat recovery (in %) | 91 |
| Maximum flow rate of RVU (in m3/h) | 450 |
| Electrical power input at Qmax (in W) | 206 |
| LwA - Sound power level (in dB(A)) | 49,0 |
| Reference flow rate (in m3/s) | 0,08750 |
| Reference pressure (Pa) | 50 |
| SPI (in kW/m3/h) | 0,17 |
| CTRL control factor (in %) | N/A |
| Typology of regulation | Local demand control |
| Max. internal and external leakage rate (%) of BVUs | <5% internal / <5% external |
| Filter alarm information | See manual |
| Regular replacement of filters for unit performance and efficiency | See manual |
| Installation instructions for ventilation grilles | N/A |
| Pre-assembly/disassembly instructions (internet) | See manual |
| Airflow sensitivity to pressure variations at + 20 Pa | N/A |
| Airflow sensitivity to pressure variations at - 20 Pa | N/A |
| Etanchéité à l'air intérieur/extérieur (m3/h) | N/A |
| Consommation électrique annuelle KWh/an | 1,37 |
| Climat moyen – EAC – Economie annuelle de chauffage (kWh/m2.an) | 47,14 |
| Climat froid – EAC – Economie annuelle de chauffage (kWh/m2.an) | 92,22 |
| Climat chaud – EAC – Economie annuelle de chauffage (kWh/m2.an) | 21,32 |
| Parameter | Value |
|---|---|
| VMI® model designation | EYOTA 600 CO2 LH et EYOTA 600 RH |
| Supplier name | Ventilairsec |
| Energy class | A+ |
| Average climate – SEC – Specific energy consumption (kWh/(m2 a)) | -43.31 |
| Cold climate – SEC – Specific energy consumption (kWh/(m2 a)) | -87.99 |
| Warm climate – SEC – Specific energy consumption (kWh/(m2 a)) | -18.16 |
| Flow type | Double flow |
| Declared typology | RVU/BVU |
| Type of drive installed or intended | Variable speed |
| Type of heat recovery system | Heat recovery |
| Thermal efficiency of heat recovery (%) | 89 |
| Maximum flow rate of RVU (m3/h) | 600 |
| Electric power input at Qmax (W) | 338 |
| LwA – Sound power level (dB(A)) | 56.0 |
| Reference flow rate (m3/s) | 0.11669 |
| Reference pressure (Pa) | 50 |
| SPI (kW/m3/h) | 0.22 |
| Control factor CTRL (%) | N/A |
| Control typology | Local demand control |
| Max. internal and external leakage rate (%) of BVUs | <5% internal / <5% external |
| Filter alarm information | See manual |
| Regular filter replacement for unit performance and efficiency | See manual |
| Installation instructions for ventilation grilles | N/A |
| Preassembly/disassembly instructions (internet) | See manual |
| Airflow sensitivity to pressure variations at + 20 Pa | N/A |
| Airflow sensitivity to pressure variations at - 20 Pa | N/A |
| Indoor/outdoor airtightness (m3/h) | N/A |
| Annual electricity consumption (kWh/a) | 1.64 |
| Average climate – AHS – Annual heating saving (kWh/(m2.a)) | 46.73 |
| Cold climate – AHS – Annual heating saving (kWh/(m2.a)) | 91.41 |
| Warm climate – AHS – Annual heating saving (kWh/(m2.a)) | 21.13 |